A manifold that passed a 350 bar hydrostatic test leaked at 20 bar on the bench. The O-ring was the right size, the right compound, from the same batch as the previous thousand units. The groove was 0.2 mm too narrow. Squeeze was fine at 22%; gland fill was 96%. With nowhere to displace, the ring behaved like a solid block of rubber, took a permanent set in the shape of the groove, and never recovered enough to seal at low pressure.
Compression percentage gets all the attention and gland fill gets the blame. Both are simple arithmetic, both are usually calculated once by whoever designed the groove and never checked again when the material changed. This is the calculation, worked through with real numbers, plus the corrections that the basic formula leaves out.

The Three Formulas
Everything in O-ring gland design reduces to three ratios and one area comparison. They are independent: a gland can have perfect squeeze and fail on fill, or perfect fill and leak because there is no squeeze left after thermal contraction.
| Quantity | Formula | Inputs | What it tells you |
|---|---|---|---|
| Squeeze (compression) | S = (W − H) / W × 100 | W = free cross-section, H = groove depth | How much the section is deformed at assembly, and therefore the contact stress available to seal |
| Stretch | E = (Dgroove − ID) / ID × 100 | Dgroove = groove diameter the ring sits on, ID = free inside diameter | Whether the ring is pre-tensioned, and how much its cross-section thins as a result |
| Gland fill | F = (0.7854 × W²) / (H × L) × 100 | L = groove width | What fraction of the groove volume the ring occupies before it swells or expands |
| Free space | 100 − F | — | Room left for thermal expansion and fluid swell |
The 0.7854 is π/4, the area of a circle in terms of its diameter. If you are working in inches, the formula is identical and the units cancel. What does not cancel is the groove corner radius: a groove with 0.2 to 0.4 mm radii holds slightly more volume than the rectangle suggests, so a calculated fill of 78% is really nearer 75%. That is a small correction, and it is why designs that calculate to 80% often work while designs that calculate to 90% never do.
A Worked Example
Take AS568-275, a 1/8 inch section ring: 3.53 mm cross-section, 266.29 mm inside diameter. It is a convenient size because the standard groove dimensions for it are published, for example in this published gland design table, and the arithmetic is easy to follow.
| Step | Face seal (static) | Piston seal (dynamic) | Rod seal (dynamic) |
|---|---|---|---|
| Cross-section W | 3.53 mm | 3.53 mm | 3.53 mm |
| Groove depth H | 2.69 mm | 2.77 mm | 2.77 mm |
| Squeeze | 23.8% | 21.5% | 21.5% |
| Groove width L | 4.75 mm | 4.75 mm | 4.75 mm |
| Ring area (π/4 × W²) | 9.79 mm² | 9.79 mm² | 9.79 mm² |
| Groove area (H × L) | 12.78 mm² | 13.16 mm² | 13.16 mm² |
| Gland fill | 76.6% | 74.4% | 74.4% |
| Free space | 23.4% | 25.6% | 25.6% |
Both are healthy. The face seal runs slightly fuller because the groove is shallower, which is normal for a static joint where the ring never has to slide. The dynamic grooves are cut 0.08 mm deeper to reduce friction and to leave room for the ring to roll slightly as pressure reverses.
Now run the same arithmetic on a gland that failed. Groove 2.3 mm deep, 3.6 mm wide, same ring: squeeze becomes 34.8%, which is already over the limit for a static joint, and fill becomes 9.79 / 8.28 = 118%. A fill above 100% is not a design with tight tolerance; it is a design that cannot be assembled without shearing the ring, and that will extrude somewhere the first time it sees pressure. Numbers like that come from a groove drawn around an available cutter rather than from the seal catalogue, and they are more common than the industry admits.
Target Bands and Why They Differ
The bands below are the ones used across most fluid power and general industrial practice, and they track the recommendations in the Apple Rubber design guide and the major seal catalogues. They are starting points, not law: a gas application at 300 bar needs more than a water line at 3 bar.
| Application | Squeeze | Stretch | Max gland fill | Reason for the band |
|---|---|---|---|---|
| Static, liquid | 15–30% | 0–5% | 85% | No sliding, so a fuller groove is tolerable; high squeeze gives low-pressure sealing |
| Static, gas | 20–30% | 0–2% | 80% | Gas molecules are small; more contact stress is needed to close the leak path |
| Dynamic, reciprocating | 10–20% | 0–3% | 75–85% | Friction and wear limit squeeze; the groove must let the ring move |
| Dynamic, rotary | 2–5% | −2–0% | 75% | Heat build-up at the contact line; low squeeze and slight interference fit |
Two of these deserve explanation. Rotary seals run almost without squeeze because the surface speed generates heat faster than the elastomer can dissipate it, and a heavily squeezed ring on a rotating shaft will fail by thermal degradation rather than by wear. And the gas band is higher than the liquid band for a reason that is easy to demonstrate: pressurise a joint with 15% squeeze on air and it will leak at 2 bar, while the same joint holds 100 bar of oil.
Stretch is the quiet one. A ring stretched 8% over its groove has its cross-section reduced by roughly the same proportion in the radial direction, which eats into the squeeze you calculated. The usual rule is to keep stretch at or below 5% for static radial joints and below 3% for dynamic ones, and to avoid negative stretch (a ring larger than its groove) except in rotary service, where a slight interference is deliberate.

Where the Simple Numbers Break Down
The formula assumes the ring and the groove at 20 °C in a dry assembly. Three effects move the answer after commissioning, and each one can be calculated.
Thermal expansion. An elastomer expands about ten times as much as steel for the same temperature rise, a ratio that the Trelleborg sealing design material uses as a starting assumption in its groove calculations. A 60 K rise increases the cross-section by roughly 0.8%, which is about one percentage point of squeeze, and it increases the cross-sectional area by 1.6%, which adds 1.6 points of gland fill. On a design at 80% fill that is enough to matter. This is why high-temperature joints are designed nearer 70% fill and why the groove depth matters more than the groove width in hot service.
Fluid swell. A compound that swells 10% by volume in the process fluid adds 10% to the ring area. The 76.6% fill in the worked example becomes 84.2%, still inside the static limit but outside the dynamic one. Swell data is measured per compound per fluid at a stated temperature, usually 70 h or 168 h immersion, and it should be read at the operating temperature rather than at ambient. A 10% figure at 23 °C can be 18% at 80 °C.
Compression set. Rubber does not return fully after being compressed hot for a long time. A nitrile ring held at 100 °C for 1,000 hours can lose a quarter of its squeeze to set. Design at 25% squeeze and lose a quarter of it and you are at 18.75%, which still seals; design at 15% and the same loss leaves 11%, which will weep at low pressure. This is the argument for the upper half of the static band, and for specifying a low-set compound where the joint runs hot. The measurement method is ASTM D395 Method B, and a compound quoting below 15% set after 22 h at 175 °C is a different product from one quoting 30%.
There is a fourth effect that the formula cannot capture: pressure. Above a certain differential, the ring is pushed against the downstream groove wall and into the clearance gap, where it extrudes. Squeeze does not prevent that; a backup ring or a smaller gap does. If you are calculating squeeze and ignoring extrusion, you are checking one of two failure modes.
What Happens Above 85% Fill
Overfill is not a gradual problem. Once the free space is gone, the ring stops behaving like a seal and starts behaving like a confined fluid.
First it cannot move. An O-ring seals by being pushed against the low-pressure side of the groove, which requires clearance to slide into. A ring that fills the groove is held by friction against both walls and cannot follow the pressure.
Second, any volume increase has to go somewhere. Thermal expansion or swell in a full groove raises the internal pressure until the elastomer finds the weakest path, which is the extrusion gap. The ring nibbles, a fragment shears off, and the joint leaks through the fragment’s void.
Third, the set becomes permanent. Rubber compressed with no room to relax takes a set in the compressed shape, and on disassembly the ring is flat on two sides and will not seal again even in a good groove. When we see a returned ring with two parallel flats and a square edge, the report usually says “material failure”. It is a groove volume failure.
The practical rule: leave at least 10 to 15% free volume in a static groove and 15 to 25% in a dynamic one, then check again with swell and thermal expansion included. If the answer is above the limit, widen the groove before you change the compound. A wider groove costs nothing at the drawing stage and a material change rarely recovers the margin.
Checks for the Drawing
Six lines on a drawing prevent most of the failures described above, and none of them is difficult to write.
- Groove depth and width with tolerances, not just nominal values, so the squeeze band can be checked at both extremes.
- Cross-section with its standard tolerance; for a 3.53 mm section that is typically ±0.08 mm, and it is part of the squeeze stack.
- Calculated squeeze minimum and maximum at the tolerance limits, written as a range, for example 18 to 26%.
- Calculated gland fill including a stated swell allowance for the named fluid.
- Surface finish and corner radii: 0.8 µm Ra or better on sealing faces, 1.6 µm on the groove bottom, no sharp edges.
- The standard the ring is made to. ISO 3601 and AS568 fix dimensions and tolerances; they do not fix compound, and both should appear.
If the joint runs hot, add the compression set limit for the compound and the temperature at which it was measured. If it runs in a fluid that swells the elastomer, add the swell figure at operating temperature. Those two numbers, not the durometer, decide whether a joint that passed a bench test survives a year in service. Our O-ring range is moulded to AS568 and ISO 3601 dimensions, and we will run the squeeze and fill arithmetic against your groove drawing before quoting if you send both.
Key Takeaways
- Squeeze is (W − H) / W; gland fill is ring area divided by groove area; both need calculating, not assuming.
- The published bands exist because static, reciprocating and rotary seals fail for different reasons: low-pressure leakage, friction and wear, and heat.
- An AS568-275 in a standard face groove gives 23.8% squeeze and 76.6% fill; in a standard dynamic groove, 21.5% and 74.4%.
- Add 1.6 points of fill for a 60 K temperature rise, and 10 points for 10% volume swell, before comparing against the limit.
- Above 85% fill the ring cannot slide, cannot absorb expansion, and takes a permanent set. Widen the groove rather than changing compound.
- Compression set is a design input. A joint that loses a quarter of its squeeze to set must start with enough to spare.