A dry gas seal on a refinery recycle compressor holds back 80 bar of hydrogen-rich gas with faces separated by a film three to five micrometres thick. That is roughly one twentieth of a human hair, and the faces never touch. A liquid-lubricated seal on a cooling water pump of the same shaft diameter runs with its faces far closer, often in partial contact, and is expected to last five years. Two cartridges, similar housings, similar secondary O-rings, and design rules that run in opposite directions.
Most of the confusion in gas seal specification comes from treating the two as the same product with a different fluid. They are not. The gas film is generated by geometry that compresses its own working fluid, it collapses below a threshold speed, and it tolerates almost no solid contamination. This article works through the mechanics that separate the two designs, then the parts we actually make and supply for gas service: the secondary seals, the gaskets, the PTFE and PEEK components that sit inside somebody else’s cartridge. If you are writing a seal specification, buying secondary seals for a gas seal refurbishment, or trying to work out why a dry-running seal failed at 400 hours, the sequence below is the one to follow.

Two Films, Two Mechanisms
Start with viscosity, because everything else follows from it. Air at 20 °C has a dynamic viscosity of about 1.8 × 10-5 Pa·s, a figure you can look up in any fluid property table, for example the air viscosity data published by The Engineering ToolBox. An ISO VG 46 hydraulic oil at 40 °C sits near 4 × 10-2 Pa·s. That is a factor of roughly two thousand, and it is the reason a gas seal cannot simply be a liquid seal running on air.
The load a viscous film can carry scales with viscosity times surface speed divided by the square of the film thickness. Put the numbers in and the problem becomes obvious: with two thousand times less viscosity, a gas film would need either two thousand times the speed or a dramatically thinner gap to carry the same load, and neither is available. A thinner gap is impossible because the surfaces are lapped to about one micrometre flatness and carry machining and thermal distortion of the same order. Higher speed is impossible because compressors already run at the limit of what the rotor will take.
So gas seals do not rely on viscous shear at all. They machine grooves into one face, typically logarithmic spirals 3 to 10 µm deep, and use rotation to pump gas inward until the pressure at the groove root balances the spring and pressure load pushing the faces together. The grooves are a built-in compressor. That is why a gas seal face is a patterned part rather than a plain lapped ring, and why the pattern, its depth and its angle are the proprietary core of every gas seal design on the market.
The compressibility of the working fluid then works in your favour. When the gap closes, the gas in it is compressed, density rises and the opening force rises faster than the closing force. When the gap opens, the opposite happens. A gas film is therefore stiff, self-correcting and stable over a wide load range, which is why a well-fed dry gas seal can hold a constant three-micrometre gap for years while the process pressure swings by tens of bar. A liquid film is far less stiff, and a liquid seal controls its gap through balance ratio, spring load and face geometry rather than through the fluid itself.
Lift-Off Speed Sets Your Operating Envelope
A gas film needs surface speed to exist. Below a threshold, the grooves cannot build enough pressure and the faces run in contact, which is a boundary-lubrication regime dressed up as a seal. Vendors usually quote this as a minimum circumferential velocity, commonly around 250 ft/min, or about 1.3 m/s, and published notes on gas-lubricated seal operation are a useful cross-check when a supplier’s figure looks optimistic. On a 100 mm shaft that is roughly 240 rpm; on a 200 mm shaft it is half that. Some catalogue figures are given as a band of 500 to 1,500 rpm because the threshold follows diameter rather than a fixed speed.
The practical consequence is that the start and stop cycle, not the running hours, consumes most of a gas seal’s life. Every start drags the faces together until lift-off, and every stop does the same in reverse. A compressor that starts twice a week for ten years accumulates a thousand contact events; one that starts twice a day accumulates seven thousand. This is why gas seal specifications for cycling machines include a start count in the purchase requirement, why a nitrogen purge on shutdown matters, and why slow-roll during commissioning without seal gas is one of the fastest ways to destroy a set of faces.
Rotation direction is the second trap. A spiral groove pumps in one direction only. Run it backwards and the groove evacuates instead of pressurising, the film collapses and the faces grind. Bidirectional patterns, usually chevron or herringbone, solve this for machines that can reverse or coast down backwards, at some cost in pumping efficiency. If your driver can be bumped in the wrong direction during maintenance, specify bidirectional grooves or interlock the rotation.
What Actually Changes in the Seal Chamber
The table below is the one worth pinning above a desk. It is not a complete design guide, but it captures the parameters where a gas seal and a liquid seal diverge, and the direction of each change.
| Parameter | Liquid-lubricated seal | Dry gas seal |
|---|---|---|
| Film thickness at running condition | Below 1 µm, often partial contact | 3–10 µm, no contact |
| What generates the film | Viscous shear plus hydrostatic pressure | Groove pumping plus gas compressibility |
| Minimum speed to work | No hard floor; seals at standstill | About 1.3 m/s surface speed |
| Leakage expressed as | Drops per minute, or g/h in a test | Nm³/h of gas |
| Heat removal | Circulating liquid carries heat away | Gas flow only; faces run hot |
| Filtration requirement | Coarse; the fluid flushes particles | 0.3–1 µm absolute, non-negotiable |
| Contamination tolerance | Moderate, with wear as the penalty | Almost none; a 2 µm particle is a boulder |
| Surface speed ceiling | Limited by heat generation and PV | Above 100 m/s on large compressors |
| Friction power | Baseline | An order of magnitude lower or better |
| Dominant failure mode | Face wear, chemical attack, heat | Gas supply faults, particles, secondary seal set |
Read the filtration row twice. In a liquid seal, a particle that gets between the faces is carried away or embedded in the softer face; the seal survives with a wear mark. In a gas seal the film is 3 to 10 µm, so anything above about half a micrometre is comparable to the gap itself and acts as a three-body abrasive that cuts the groove pattern. A single dirty startup can remove the geometry that generates the film, after which the seal runs on its faces and fails within days. Filtration and dew point control are not housekeeping items on a gas seal; they are the seal.
Face Materials: What Gas Service Allows
The standard gas seal pair is silicon carbide running against carbon-graphite, or SiC against SiC for higher duty. Carbon-graphite earns its place because it is self-lubricating: its dry friction coefficient sits between roughly 0.04 and 0.15, low enough that the brief contact at every start does not destroy the face. It also has enough porosity control to be impregnated, and the impregnation matters: seal-grade graphite is specified below about 2% porosity after impregnation, because gas molecules migrate through connected pores in a way that liquid does not.
Silicon carbide brings hardness, thermal conductivity and corrosion resistance, and it can be lapped to the flatness the film needs, on the order of one micrometre across the face, which is a couple of light bands on an optical flat. Tungsten carbide appears where thermal shock or impact is the concern. Diamond-coated SiC exists for abrasive duties, and it is worth the money only when the alternative is replacing faces every quarter.

Two materials decisions are made by the fluid rather than by the load. Wet chlorine, wet hydrogen sulphide and some amine services attack the binder phase in cemented carbides; SiC grades differ in how much free silicon they contain and therefore in how they behave in hot caustic. And any gas that can condense inside the seal, whether a heavy hydrocarbon or water, changes the problem from dry running to two-phase running, which no face material solves. Check the dew point at seal chamber pressure, not at line pressure, before you choose the pair.
Secondary Seals Are Where Refurbishments Go Wrong
The secondary seals are the parts we supply, and they are also the parts most often specified by copying the previous order. In a gas seal cartridge the secondary seal has to hold process gas at pressure, survive a temperature that swings with load, resist swelling in a light hydrocarbon, and not blister when the machine depressurises. Those are four different requirements and they do not point at the same compound.
The temperature question is not the process temperature on the data sheet. A gas seal face generates heat by shear in the film and loses heat only through the gas it leaks, so the metal around the secondary seal runs hotter than the process line on a high-pressure machine and colder during a depressurisation through a Joule-Thomson cooling path. The secondary seal is the first part to show that history: it comes out hard, shiny and permanently deformed, with a compression set above 40% and a cross-section that no longer fills the groove. If you are choosing a compound from the line temperature alone, you are choosing for the wrong number.
The second requirement is rapid gas decompression resistance. Under pressure, gas dissolves into the elastomer until it reaches equilibrium; when the seal chamber is vented quickly, that gas expands inside the material faster than it can diffuse out, and the result is blisters, internal cracks and a seal that leaks on restart. The test standard is ISO 23936-2, harmonised with the NORSOK M-710 methodology, and it is the only evidence worth accepting for gas duty. Compounds that pass typically combine a higher hardness, a higher modulus and low swell; a standard 70 Shore A NBR that is perfect in a hydraulic cylinder is a poor choice here even though the groove dimensions are identical. Suppliers of oilfield-grade elastomers publish these ratings per compound, and the Precision Polymer Engineering material data is a reasonable reference point for what an RGD-rated sheet actually contains.
| Duty in the cartridge | Secondary seal | Why | Watch out for |
|---|---|---|---|
| Hydrocarbon gas to 100 °C, moderate pressure | NBR 90 Shore A, RGD-tested | Good swell resistance in aliphatic gas, low cost | Not for aromatic or polar service; check swell data |
| Gas to 200 °C, amine or acid gas | FKM 90 Shore A, low compression set | Temperature and chemical envelope | Poor in low-temperature starts; hot tear on assembly |
| Gas to 260 °C, aggressive chemicals | FFKM 90 Shore A | Widest chemical and thermal range | Cost; confirm RGD rating, not just temperature |
| Cryogenic or very high temperature, dry | Spring-energized PTFE | No elastomer ageing, wide temperature range | Needs preload; groove finish and concentricity matter |
| Large diametral clearance, high pressure | O-ring plus backup ring | Prevents extrusion into the gap | Backup ring material must match the gas, not just the pressure |
The groove itself is half the problem. An O-ring that is correct in compound still extrudes if the diametral clearance is too large for the pressure, and in gas service the extrusion gap opens as the housing heats. That is what backup rings are for, and the material choice follows the gas: filled PTFE where chemical resistance dominates, PEEK where the temperature or the pressure rules out PTFE. Our own O-ring and X-ring range is moulded in the same compounds used for these cartridges, and the X profile is worth considering where the secondary seal sees rotation or a slow stroke, because it needs less squeeze to seal and resists rolling in the groove.
Support Systems Decide the Outcome
A gas seal is a system component. The cartridge is perhaps a third of the reliability, and the gas conditioning upstream is the rest. Tandem arrangements use a buffer gas between the primary and secondary seal, typically nitrogen at a pressure slightly below the process so that any cross-flow goes inward rather than out. Double arrangements use a barrier gas above process pressure, at a minimum of about 25 psi above the seal chamber, so that the only thing escaping to atmosphere is the barrier gas. The choice between them is a decision about what may reach the atmosphere, not about seal performance, and the piping conventions behind each are worth reading in a cartridge maker’s plan drawings before you design the panel; Flowserve’s published seal support documentation covers the API plan set in more detail than most specifications do.
Three numbers in the supply specification decide whether the cartridge lives. Filtration, absolute, at 0.3 to 1 µm with differential pressure indication. Dew point, low enough that nothing condenses at seal chamber pressure, with the gas often heated 20 °C above its dew point as a margin. And pressure control, stable enough that the film is not asked to survive a 10 bar step. A seal that is starved of gas for thirty seconds during a control valve failure will usually survive; one that is starved repeatedly will not, and the faces will show it as a ring of polished contact rather than the damage pattern of a particle.
| Supply parameter | Typical requirement | What fails if it is missed |
|---|---|---|
| Filtration | 0.3–1 µm absolute, with dP alarm | Groove erosion, three-body wear, rising leakage |
| Dew point | At least 10 °C below the coldest point at seal pressure | Condensate on faces, two-phase running, film collapse |
| Buffer or barrier pressure | Tandem: slightly below process. Double: 25 psi above chamber | Process gas to atmosphere, or barrier gas into process |
| Temperature | 20 °C above dew point at the seal inlet | Hydrate or ice formation at the restriction |
| Flow indication | Measured, alarmed, trended | Silent starvation after a filter change |
For context, the ISO 8573-1 compressed air classes that plants use for instrument air are a reasonable vocabulary for talking about this: Class 2 is a pressure dew point of −40 °C and 0.1 mg/m³ oil, and most gas seal buffer supplies are specified tighter than that on particulates. If your plant cannot state its seal gas cleanliness as a class with a number against each of the three contaminants, the specification is not finished.
Where Liquid Seals Still Win
Gas seals are not universally better, and a supplier who says they are has not been on a slurry pump. Four service conditions keep liquid seals in place.
Low speed is the first. Below the lift-off threshold there is no gas film, so a slow-running machine gains nothing and loses the cooling that a liquid film provides. Dirty service is the second: a gas film cannot flush abrasive particles away, and no practical filtration protects a seal on a stream that is itself a suspension. High-viscosity fluids are the third, where the liquid is easy to film and the gas equivalent would need heat to vaporise. The fourth is simply the absence of a clean, dry gas supply at the right pressure, which is common on remote or small installations where a nitrogen system would cost more than the pump.

There is also a cost argument that gets ignored in comparisons. A dry gas seal cartridge is expensive, and the support system, the gas consumption, the filters and the instrumentation add a capital and operating cost that only amortises on large machines running continuously. On a small pump handling a benign fluid, a liquid seal with a proper plan and a spare cartridge in the store is the engineering answer, not a compromise.
Reading the Faces After a Failure
The face damage pattern usually names the cause, and the three patterns below cover most of what arrives on our bench with a customer asking for new secondary seals.
Radial cracks and a heat-discoloured carbon face mean thermal overload. The film was too thin for the load, or the gas supply was interrupted while the machine kept running. Look for a matching heat mark on the SiC and check whether the seal gas pressure alarm was inhibited.
A polished ring on both faces, with the groove pattern still visible but the land area shiny, means contact running rather than film failure. Either the machine ran below lift-off speed for long periods, or it was started and stopped far more often than the design assumed. Secondary seals in these cartridges usually look fine, which is why the fault is often misdiagnosed as a seal quality problem.
Grooves with rounded edges, a matt finish and a ring of embedded debris mean particles. In that case the secondary seals will show the same debris embedded in the elastomer, and the fix is upstream at the filter, not in the cartridge. When a set of secondary seals comes back swollen, blistered or hard, the question to ask is not which compound was used but what the decompression rate and the gas composition actually were.
What to Put on the Secondary Seal Drawing
Most of the disputes we settle start with a drawing that names a material and a size and nothing else. These are the fields worth writing, in the order that matters.
- Compound and hardness, with the RGD standard and the acceptance criteria, not just the material family.
- Gas composition, including the minor components that decide swell: aromatics, carbon dioxide, hydrogen sulphide, water.
- Operating temperature range at the seal, both the steady state and the excursion during depressurisation.
- Pressure, and the maximum decompression rate the seal must survive.
- Groove dimensions and diametral clearance, so the extrusion gap is defined rather than assumed.
- Backup ring material and orientation, if one is used.
- Surface finish of the groove, and whether the housing is stainless or a coating.
- Lubricant permitted at assembly, and whether it must be compatible with the process gas.
Two of these are commonly omitted and both cause failures: decompression rate, and the minor gas components. An elastomer that is perfect in dry methane can swell 20% in a stream with 3% carbon dioxide and aromatics, and a swelled O-ring in a fixed-volume groove increases gland fill until the material has nowhere to go.
Questions We Get Asked About Gas Seals
Can a dry gas seal run on compressed air instead of nitrogen? Yes, if the air is dry and clean enough, and many air compressor and blower seals do exactly that. The limits are the dew point and the oil carry-over. Air at a pressure dew point of −40 °C and oil below 0.1 mg/m³ behaves much like nitrogen. Wet plant air destroys faces in weeks.
Why not fit a liquid seal to a compressor and avoid the gas system? Because the seal oil becomes the contamination. On a process gas compressor, oil ingress degrades catalysts and product, and the oil circulation system itself is a maintenance burden with pumps, coolers and reservoirs. Dry gas seals removed that whole subsystem, and the reliability gain came from removing it rather than from the faces.
What actually leaks to atmosphere from a tandem gas seal? Normally nothing from the process. The primary seal leaks a small amount of process gas into the buffer chamber, where it is vented or flared, and the secondary seal holds the buffer gas. In a double arrangement the barrier gas is what escapes, at a rate measured in normal cubic metres per hour.
How much gas does the support system consume? Enough that it appears in operating cost. A large compressor seal can pass several normal cubic metres per hour of buffer or barrier gas, and the number matters when nitrogen is purchased. It is one reason the seal gas supply is often taken from the process rather than from a nitrogen header.
Can a gas seal survive a liquid slug? Not reliably. Liquid entering the gap fills it, the grooves stop pumping gas, and the faces run with liquid between them at a fraction of the designed film. Some designs tolerate a brief carry-over; none tolerates repeated slugs. If carry-over is credible, the answer is a knockout drum and a high-level trip, not a different seal.
Are the O-rings in a gas seal the same as hydraulic O-rings? Same shape, different compound and different evidence. A hydraulic NBR at 70 Shore A will seal gas at low pressure, and it will also blister on decompression and harden at the temperatures a gas seal housing reaches. Ask for the RGD report, the compression set figure and the swell data in the actual gas.
What is the single most common cause of early gas seal failure? In our experience with the secondary seals that come back, it is gas supply: a blocked filter element, a dew point that was never as low as the data sheet said, or a buffer pressure that was set once and never re-checked. The faces are usually the messenger.
If you are specifying secondary seals for a gas seal refurbishment and the drawing has a material name but no RGD requirement, the cheapest thing you can do is fix the drawing before you order. Send us the gas composition and the decompression rate and we will tell you which compound we would put in the groove, and what evidence we can supply with it. The spring-energized seal range covers the dry and extreme-temperature cases where an elastomer is the wrong answer, and the high and low temperature seal range covers the rest.